Fire fighting system design calculations

These basic procedures can also be used for calculating many other types of systems such as fire hydrant , hose reel or the discharge from a water cannon or monitor we can also use the same principal for almost all other water-based fire protection systems if we have a k-factor for the output device ( fire sprinkler , water mist nozzle and so on). Many type of fire fighting systems base on occupancy and application,in our fire fighting design course deal with almost common system ( water system ). Each one from the above three category take you from began to next level of system acknowledgment. How-ever, because automatic sprinklers are use the water is usually stopped from flowing unless heat from the fire has also activated one or more sprinklers. Design of fire fighting systems with carbon dioxide – Calculation of necessary quantities.


High pressure systems are mostly used nowadays.

In these systems , carbon dioxide is stored in pressure containers at a controlled low temperature of degF (or -degC). Low pressure systems are used in special applications,. The total number of hose reels on the platform will be seven. With a maximum of five reels being used on the lower deck for one fire and allowing a maximum flow rate of lbs. Fire Protection Engineering (FPE), and fire prevention.


Fire protection is concerned with preventing or minimizing the direct and indirect consequences of fire on people, property, and programs. The minimum design in such spaces shall be the greater of 000SF or sprinklers for wet systems , and 600SF or sprinklers for dry systems. NOTE: The Appendix of NFPA includes suggested lists of occupancies categorizde by fire hazrd as a being Light, Ordinary (Group 1), etc.

A review of the fire extinguishing capabilities of the system vs. Area: ( 2gpm. ) x ( min.) = 6sq. Under normal conditions, an eight-pile platform will not have potential spill areas (drip pans etc.) in excess of 6ft.


For fire suppression systems flow calculations consist of determining nozzle pressures, discharge times and the quantity of agent discharged from each nozzle. Each of these items has a special relation to the problem of extinguishing fires. Inert gas systems operate at relatively high storage pressures. The calculations are related to fire safety in buildings and to the safe relation of buildings to other risks.


Some are simple, some complex. Fire Alarm Control Panels Fire Pump Performance Curves Sizing the Fire Pump Detailing the Pump Plan Installation Considerations Fire Pump Testing Apparatus Endnotes 19. Jockey pump or pressure maintenance pump is a small apparatus that works in conjuction with a fire pump as part of a fire -protection sprinkler system.


It is designed to keep the pressure elevated so that the main fire pump is prevented from running unless absolutely necessary. This project is being undertaken in response to a request from ODPM Fire Statistics and Research Division (FSRD) to undertake a number of hydraulic calculations on wet and dry risers in high rise buildings. This report provides of sample calculations using a BRE software package “Riser flow” to calculate water flows in wet and dry risers.


Earlier, piping design was done by using many manual calculations and formulation methods. This made piping design a laborious and time-consuming process and it was also prone to large amount of errors. Hydraulic calculation for fire protection engineers.


It is important for fire protection engineers and designers to understand the hydraulic calculations and analysis principles to be fully gain the benefits of using full hydraulic calculations in fire protections systems such as fire sprinkler, water mist and other types of water base extinguishing systems.

Centrifugal pump design is the most typical for Fire Pumps and Auxiliary Pumps in modern fire apparatus and its proven design has been used in fire apparatus for well over a century. In a basic centrifugal pump, typically a single casing, water enters through the pump inlet into the center (eye) of the impeller which is spinning on a shaft.